INTRODUCTION

L AND T O W HICH T HIS SECTION OF THE PL AN A PPLIES

A IMS AND O BJECTIVES OF THIS SECTION OF THE DC P

Ensure that new development will alleviate travel demand, support the efficient and effective operation of public transport and improve access to housing and employment. vii) Ensuring a safe and high-quality usable environment for employees, visitors and residents who use the City Center; and. viii) Ensure that all development incorporates the principles of ecologically sustainable development. ix) Ensure that water management is an important aspect of planning.

R ELATIONSHIP W ITH O THER PLANS P OLICIES AND D OCUMENTS

DEVELOPMENT CONTROLS

  • D ESIRED P LANNING O UTCOMES F OR T HE T OWN C ENTRE
  • U RBAN S TRUCTURE
  • B UILDING F ORM
  • S TREETSCAPE
  • A RTICULATION
  • A WNINGS
  • C ORNER B UILDINGS
  • P EDESTRIAN E NTRANCES & E XITS
  • R OOF D ESIGN
  • BUILDING HEIGHT
  • C EILING H EIGHTS
  • F INISHES
  • O UTDOOR E ATING
  • C ULTURE AND P UBLIC A RT
  • M IXED U SE C OURTYARD B UILDINGS
  • S AFETY & S ECURITY
  • L IGHTING
  • A COUSTIC
  • S ITE F ACILITIES AND S ERVICING
  • S OLAR A CCESS

A vibrant mixed-use character, activating all areas of the city center and providing opportunities for informal surveillance, enhancing security. To provide a range of uses to engage and activate the street and contribute to the economic viability of the city centre. ii). Elevation plane follows the topography of the site and is measured along the site boundaries.

Taking care of the design of the houses on the site. has taken into account the impact of the major roads adjacent to the site; iv).

Figure 2 Structure Plan
Figure 2 Structure Plan

PRECINCT CONTROLS

P RECINCT O BJECTIVES

To accommodate the foreseeable expansion of retail, commercial and residential development within the town centre. iii). To ensure that the town center develops in a coherent and logical manner in accordance with the Ward Diagrams and illustrations. ii). To improve pedestrian amenity and links within the town center through the provision of canopies, courtyard buildings and pedestrian links. iii).

To enhance the appearance of the town center by providing architectural features and facade articulation. iv). To emphasize important locations and intersections in the town center by including landmark corner buildings. f). To ensure that the bus interchange on Old Northern Road can be easily integrated into the town centre. i).

To protect the heritage of the city centre. ii) Revitalize and enhance heritage buildings through landscaped pedestrian areas and appropriate adaptive reuses. iii). To improve the permeability and accessibility of the city center by providing pedestrian links through the city centre. ii). To improve the amenity and appearance of all streetscapes and development within the town centre. ii) Ensure that setback areas are treated as extensions of the public pedestrian area. iii).

C ENTRAL P LACE P RECINCT

Landmark buildings should be of an appropriate architectural quality that uses a variety of physical and design elements to achieve buildings of character and interest. Levels above two storeys with direct street frontage to Old Northern Road should be stepped back to reduce the bulk and scale when viewed from the street. Buildings will be set back on Old Northern Road to allow for wide canopies and landscaping.

The continuous line of construction on Old North Street should be preserved to reinforce the traditional character of the belt's main street. Vehicular access should be from Central Place and Olive Street in accordance with the structure plan illustrated in Figure 10. A 24-hour publicly accessible connection to the pedestrian plaza should be provided at the central place via the block's existing pedestrian link. middle school on Old North Street. ) Ground floor uses will occupy retail/commercial uses.

First floor uses will be occupied by commercial/residential uses. a) See Clause 4.4 Floor Area Ratio of The Hills LEP 2012 and Floor Area Ratio Maps. Second and third levels Additional levels .. a) Architectural features and articulation of the facade are encouraged, especially at the corners of landmarks. WSUD best practice principles should be applied during construction and post-construction.

Figure 9 Central Place Precinct – Building Height
Figure 9 Central Place Precinct – Building Height

S TOCKLAND M ALL P RECINCT

The courtyards are intended to function as mixed-use commercial/retail spaces and provide an attractive central precinct. Water Sensitive Urban Design - Technical Guidelines for Western Sydney, May 2004, prepared by URS for UPRCT. . are required for all new commercial and residential buildings or where the increase in impervious surface above the site is greater than 150 m2. Providing improved pedestrian links to the shopping center from Olive Street and Old Northern Road.

Improved vehicular access to the site and consolidation of existing parking levels to improve vehicular circulation. Building design must ensure adequate solar access to Olive Street and use a range of physical and design elements to achieve a building of character and interest. Adequate setbacks are required on the Olive Street and Windsor Road frontages to provide wider footpaths and landscaping to enhance the public domain.

The Olive Street frontage will be embellished to provide the mall with a welcoming face and a pedestrian-friendly environment. Vehicle access is via Olive Street and Windsor Road, with service access via Windsor Road. Water Sensitive Urban Design - Engineering Guidelines for Western Sydney, May 2004, prepared for UPRCT by URS.

Figure 17 Stockland Mall Precinct – Aerial View
Figure 17 Stockland Mall Precinct – Aerial View

R AILWAY S TREET P RECINCT

Landscaping to the east elevation of Blocks 9 and 10 opposite Raemot Land Carpark will form an extension of the public footpath reserve. The main function of this area is to provide a pedestrian square that connects the main nodes of activity through the center.

Figure 21  Railway Street Precinct – Landmark Corner building
Figure 21 Railway Street Precinct – Landmark Corner building

O LD N ORTHERN R OAD P RECINCT

Mixed use development adjacent to heritage site to include commercial activities at ground level with residential above. Buildings must have a strong street edge with awnings to provide protected access to residential lobbies and ground floor commercial premises on Old Northern Road. Where appropriate, cultural heritage must be included as an active element in future development to promote an active streetscape.

The setbacks will allow for the proposed route to be widened and buses to be placed on Old North Road. New buildings should be of an appropriate architectural quality that uses a variety of physical and design elements to achieve a building of character and interest. The built form should allow opportunities for passive surveillance and an active interface with publicly accessible areas.

Relationship to heritage buildings with low podiums, horizontal cornices and other scale-breaking devices in adjacent developments. The first floor and above must be used by commercial/residential uses. a) Floor area ratios must be in accordance with the following table:-. Living room and first level Additional levels .. a) Buildings should compliment and not visually dominate adjacent heritage buildings.

Figure 24 Old Northern Road – Building Height
Figure 24 Old Northern Road – Building Height

C ONIE A VENUE R ESERVE P RECINCT

Roof form to include elements to create an interesting roofscape and skyline; sawtooth, pitched roofs, innovative skillfully curved or floating roof forms are encouraged. To ensure that appropriate provision is made for road widening along Seven Hills Road. The floor space ratio will be in accordance with Clause 4.4 Floor Space Ratio of The Hills LEP 2012 and Floor Space Ratio Chart. a) Building height shall be in accordance with Clause 4.3 Height of Buildings of The Hills LEP 2012 and LEP Height of Buildings maps.

Figure 28 Conie Avenue Reserve Precinct – Structure Plan
Figure 28 Conie Avenue Reserve Precinct – Structure Plan

W INDSOR R OAD P RECINCT

AIM OF THE WINDSOR ROAD. i) to understand the evolving nature of the Shire's urban centers contained within the area and identify their impact on economic development and the development of adjacent residential areas. ii) to produce a range of design guidelines for different housing forms that protect and enhance the garden-like character of the Shire and reflect the evolving shape of the Shire's town centres. iii) to achieve well-designed residential development that offers a high standard of amenities for its residents and adjacent property owners. iv) to facilitate the development of outstanding building design appropriate to an area. v) require parking and service provision to be contained within the development area at an amount and rate appropriate to the economic and sustainable growth of the town centre, and (vi) provide for safe and secure access. The development control will facilitate a unique development that seeks to balance quality, higher density residential living with the green, leafy suburban character of the Shire. Screening and partial enclosure of balconies is limited to provide privacy for neighbors and comfort for residents without resulting in unattractive buildings or an appearance of excessive bulk or limiting opportunities for passive surveillance of the street.. to provide setbacks that complement the surroundings and contributing to the streetscape and character of the street while allowing flexibility in the placement of buildings.. to ensure that the space in front of the building is sufficient to allow for landscaping that will complement the building form and enhance the landscape character of the street.. side and rear setbacks. shall be proportional to the slope of the site, taking into account the height and relationship between the buildings on adjacent properties. Setbacks in proposed buildings must minimize any negative impacts such as overshadowing and privacy on adjacent and neighboring properties.

The Windsor Road Precinct should be a prominent feature marking the edge of the town centre. Any future site development application should be consistent with road widening plans along Windsor Road. Architectural plans and pedestrian access arrangements for the site should take into account the possible relocation of the bus stop.

Mailboxes should be built into the wall where possible and made of materials that match the appearance of the building. Place the satellite dish and telecommunications antennas, air conditioners, ventilation ducts and all ancillary structures away from the street frontage included in the roof design and in a place where such facilities will not become a feature of the skyline at the top of the construction, adequately set back from the perimeter wall or roof edge of buildings. Container structures should be well designed and treated as part of the overall development look.

Figure 30 Windsor Road Precinct – Illustration
Figure 30 Windsor Road Precinct – Illustration

DEFINITIONS

Acoustic report assessing the design of dwellings and external noise reduction devices together must be demonstrated to achieve a maximum ambient noise level of 40 dB(A) in any habitable room. Acoustic walls facing busy arterial roads should be designed to avoid blank painted surfaces and monotonous appearance. The details of all proposed lighting, including a light spill diagram for external lighting and the hours of operation of any lighting, must be provided with the development application.

All lighting should be raised to ensure that the lights do not interfere with the movement of traffic both on the site and on nearby roads. It is measured as the horizontal distance between the proposed wall, window or outermost part of the building and the boundary. Floor Space Ratio - The floor space ratio is the total floor area of ​​all buildings divided by the total area of ​​the development area.

The only areas excluded from floor area calculations are areas used for elevator towers, cooling towers, utility rooms and built parking garages required to meet council parking standards, and loading docks. Existing Trees - any tree with a height of more than 5.0 meters and/or a width of 3.0 meters and/or a trunk diameter of 150 millimetres, measured at 1.0 meters from the trunk of the tree. Building Height (or Building Height) - means the vertical distance from ground level (extant) at any point to the highest point of the building, including factory and elevator crossings, but excluding communications equipment, antennas, satellite dishes, masts, flagpoles, chimneys, flues, and of such.

Figure

Figure 1 Land to which this Plan applies
Figure 2 Structure Plan
Figure 3 Awnings and Colonnades
Figure 4 Public Domain Strategy
+7

References

Related documents

Part 2 Permitted or prohibited development 2.1 Land use zones The land use zones under this Precinct Plan are as follows— Residential Zones R2 Low Density Residential R3 Medium